Product Description
RATO can supply Low-E double-glazed insulating glass units for window project enquiries. The exact build-up is confirmed for each proposed unit.
A double-glazed insulating glass unit generally consists of two panes separated by a spacer and sealed around the edges, leaving a cavity between the panes. A Low-E coating may be specified on a glass surface within the unit. The panes, cavity, coating and finished dimensions must be checked against the proposed configuration and the project requirements.
No. Low-E describes a coating applied to a glass surface; double glazing describes an assembly with two panes separated by a cavity. A single pane can have a Low-E coating, and a double-glazed unit can be specified with or without a Low-E coated pane. The terms describe different aspects of the glass, so an enquiry should state which assembly is required.
For a Low-E double-glazed unit, identify the coated pane and surface in the proposed build-up. Do not assume that every unit places the coating on the same surface. Confirm its position with the supplier and the project design before finalizing the specification.

| Part | What to identify in the specification |
|---|---|
| Glass panes | Each pane's type, nominal thickness and any required treatment or processing |
| Cavity and spacer | The specified cavity dimension and spacer details for the proposed unit |
| Edge seal | The edge-seal requirements and the documents relevant to the proposed unit |
| Low-E coating | Whether it is required, the coated pane and the coating surface |
| Complete unit | Finished dimensions, total thickness, tolerances and how the unit fits the frame |
Tempered glass describes heat treatment of an individual pane. Laminated glass describes panes bonded with an interlayer. Either term identifies a glass construction or treatment, not by itself the presence of an insulating cavity. If tempered or laminated glass is required in a double-glazed unit, specify the relevant pane and confirm the proposed build-up.
Review the window design, dimensions, frame and glazing pocket, installation conditions and the performance and documentation requirements for the destination. The project designer or installer should confirm the complete assembly against applicable requirements. Performance depends on the complete configuration; it should not be inferred from the words “Low-E” or “double glazing” alone.
Before an order is finalized, confirm the proposed pane types and thicknesses, cavity and spacer specification, coating position, overall thickness, tolerances and required processing. Request documents that correspond to the actual proposed configuration when the project requires them.
To discuss a unit for a window project, provide:





Destination country or region, intended use and applicable project requirements.
The proposed pane build-up, including nominal thicknesses and whether either pane needs to be tempered or laminated.
The required cavity and spacer specification, if known, and the desired total unit thickness or frame constraints.
Whether a Low-E coating is required and any design requirement for its position.
Finished panel dimensions, quantities, drawings and any required edge work, holes or other processing.
Performance criteria and any applicable test reports or certification documents required for the proposed unit.
Confirm available configurations and the documents applicable to the specific proposed unit before finalizing an order.